Buyer Name: University Of Edinburgh
Buyer Address: Charles Stewart House, 9-16 Chambers Street, Edinburgh, UKM75, EH1 1HT, United Kingdom
Contact Email: jpike2@ed.ac.uk
Contact Telephone: +44 1316502759
Buyer Name: University Of Edinburgh
Buyer Address: Charles Stewart House, 9-16 Chambers Street, Edinburgh, UKM75, EH1 1HT, United Kingdom
Contact Email: jpike2@ed.ac.uk
Contact Telephone: +44 1316502759
SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).
No linked documents found for this notice.
Lot Description: SUMMARY The University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the <1 ppb for methane, <0.5 ppb for N2O and < 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz. PAYLOAD WEIGHT AND INTERFACE To enable use of the facility’s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg. MEASUREMENT APPROACH Measurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series. To give an example of the intention; At timestamp 1, a volume of air, V1, has been ‘ingested’, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1). At timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2). And so on, at the ‘Hz’ rating the device operates at. Measurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable. CONCLUSION After a market evaluation it is believed there is only one solution which can fulfil the combined requirements – the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons. Any suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication. Value represents cost excluding VAT and import duties (if applicable).
Lot 1 Has Options: Yes
Lot 1 Options: We may source maintenance services, spare parts and upgrades for the analyser from the awarded supplier.
{
"awards": [
{
"id": "010243-2026-1",
"relatedLots": [
"1"
],
"status": "active",
"suppliers": [
{
"id": "GB-FTS-173268",
"name": "GeoGas Analytica"
}
]
}
],
"buyer": {
"id": "GB-FTS-2023",
"name": "University Of Edinburgh"
},
"contracts": [
{
"awardID": "010243-2026-1",
"dateSigned": "2026-02-04T00:00:00Z",
"id": "010243-2026-1",
"status": "active",
"value": {
"amount": 82840.0,
"currency": "EUR"
}
}
],
"date": "2026-02-05T08:56:34Z",
"description": "This succeeds prior notice to provide further clarity about the requirement\n(SC Ref:822790)",
"id": "010243-2026",
"initiationType": "tender",
"language": "en",
"links": [
{
"href": "https://api.publiccontractsscotland.gov.uk/v1/Notice?id=ocds-r6ebe6-0000822790",
"rel": "canonical"
}
],
"ocid": "ocds-h6vhtk-06478f",
"parties": [
{
"address": {
"countryName": "United Kingdom",
"locality": "Edinburgh",
"postalCode": "EH1 1HT",
"region": "UKM75",
"streetAddress": "Charles Stewart House, 9-16 Chambers Street"
},
"contactPoint": {
"email": "jpike2@ed.ac.uk",
"telephone": "+44 1316502759"
},
"details": {
"buyerProfile": "https://www.publiccontractsscotland.gov.uk/search/Search_AuthProfile.aspx?ID=AA00107",
"classifications": [
{
"description": "Body governed by public law",
"id": "BODY_PUBLIC",
"scheme": "TED_CA_TYPE"
},
{
"description": "Education",
"id": "09",
"scheme": "COFOG"
}
],
"url": "http://www.ed.ac.uk"
},
"id": "GB-FTS-2023",
"identifier": {
"legalName": "University Of Edinburgh"
},
"name": "University Of Edinburgh",
"roles": [
"buyer"
]
},
{
"address": {
"countryName": "Belgium",
"locality": "Balen",
"postalCode": "2490",
"region": "BE213",
"streetAddress": "Kneveloord 3"
},
"details": {
"scale": "sme"
},
"id": "GB-FTS-173268",
"identifier": {
"legalName": "GeoGas Analytica"
},
"name": "GeoGas Analytica",
"roles": [
"supplier"
]
},
{
"address": {
"countryName": "United Kingdom",
"locality": "Edinburgh"
},
"id": "GB-FTS-1033",
"identifier": {
"legalName": "Edinburgh Sheriff Court"
},
"name": "Edinburgh Sheriff Court",
"roles": [
"reviewBody"
]
}
],
"tag": [
"award",
"contract"
],
"tender": {
"classification": {
"description": "Pollution-monitoring devices",
"id": "38344000",
"scheme": "CPV"
},
"coveredBy": [
"GPA"
],
"description": "SUMMARY\nThe University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the \u003c1 ppb for methane, \u003c0.5 ppb for N2O and \u003c 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz.\nPAYLOAD WEIGHT AND INTERFACE\nTo enable use of the facility\u2019s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg.\nMEASUREMENT APPROACH\nMeasurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series.\nTo give an example of the intention;\nAt timestamp 1, a volume of air, V1, has been \u2018ingested\u2019, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1).\nAt timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2).\nAnd so on, at the \u2018Hz\u2019 rating the device operates at.\nMeasurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable.\nCONCLUSION\nAfter a market evaluation it is believed there is only one solution which can fulfil the combined requirements \u2013 the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons.\nAny suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication.\nValue represents cost excluding VAT and import duties (if applicable).",
"id": "NCA21386",
"items": [
{
"deliveryAddresses": [
{
"region": "UKM75"
}
],
"id": "1",
"relatedLot": "1"
}
],
"legalBasis": {
"id": "32014L0024",
"scheme": "CELEX"
},
"lots": [
{
"description": "SUMMARY\nThe University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the \u003c1 ppb for methane, \u003c0.5 ppb for N2O and \u003c 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz.\nPAYLOAD WEIGHT AND INTERFACE\nTo enable use of the facility\u2019s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg.\nMEASUREMENT APPROACH\nMeasurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series.\nTo give an example of the intention;\nAt timestamp 1, a volume of air, V1, has been \u2018ingested\u2019, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1).\nAt timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2).\nAnd so on, at the \u2018Hz\u2019 rating the device operates at.\nMeasurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable.\nCONCLUSION\nAfter a market evaluation it is believed there is only one solution which can fulfil the combined requirements \u2013 the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons.\nAny suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication.\nValue represents cost excluding VAT and import duties (if applicable).",
"hasOptions": true,
"id": "1",
"options": {
"description": "We may source maintenance services, spare parts and upgrades for the analyser from the awarded supplier."
}
}
],
"mainProcurementCategory": "goods",
"procurementMethod": "limited",
"procurementMethodDetails": "Negotiated without publication of a contract notice",
"procurementMethodRationale": "SUMMARY\nThe University of Edinburgh Field Spectroscopy Facility requires a sensor system/analyser with the capability to measure N2O (nitrous oxide), CO2 (carbon dioxide) and CH4 (methane) concentrations at altitude/height simultaneously and in real time, at a detection limit in the \u003c1 ppb for methane, \u003c0.5 ppb for N2O and \u003c 200 ppb for CO2. The concentrations are required for flux measurements, and therefore the temporal frequency of measurements is important, measurement frequency needs to be no less than 1 Hz, ideally at 5 Hz.\nPAYLOAD WEIGHT AND INTERFACE\nTo enable use of the facility\u2019s existing UAV equipment the sensor must be able to interface with a DJI M400 drone, and the total sensor weight must be under 7kg.\nMEASUREMENT APPROACH\nMeasurements of these gasses must be made simultaneously, to a synchronised timing and measurement frequency, and the measurement at a given timestamp should be taken from the same shared volume of air. This should produce a single combined data series.\nTo give an example of the intention;\nAt timestamp 1, a volume of air, V1, has been \u2018ingested\u2019, and will be tested by the analyser to give measurements of N2O(t=1), CO2 (t=1) and CH4(t=1).\nAt timestamp 2, (1 second in the future, if operating at 1 Hz), a new volume of air V2 is ingested and analysed to give measurements of N2O(t=2), CO2 (t=2) and CH4(t=2).\nAnd so on, at the \u2018Hz\u2019 rating the device operates at.\nMeasurement must be conducted in-situ/in-flight at real time while the UAV operates; storing volumes of air for after-operation analysis would not be suitable.\nCONCLUSION\nAfter a market evaluation it is believed there is only one solution which can fulfil the combined requirements \u2013 the Aeris Sensors MIRA Strato. As such we intend to award via the Negotiated Procedure Without Prior Call for Competition, to their sole EU distributor, on the basis competition is absent for technical reasons.\nAny suppliers who wish to query or challenge this notice should do so within 10 calendar days of its publication.\nValue represents cost excluding VAT and import duties (if applicable).",
"procurementMethodRationaleClassifications": [
{
"description": "The works, supplies or services can be provided only by a particular economic operator due to absence of competition for technical reasons",
"id": "D_TECHNICAL",
"scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL"
}
],
"status": "complete",
"title": "Atmospheric gas analyser"
}
}