Ultrasound Neuromodulation Device (Transducer)

University of Plymouth

Buyer Contact Info

Buyer Name: University of Plymouth

Buyer Address: Drakes Circus, Plymouth, UKK41, PL4 8AA, United Kingdom

Contact Email: supplier@plymouth.ac.uk

Status
complete
Procedure
direct
Value
337000.0 GBP
Published
20 May 2025, 16:18
Deadline
n/a
Contract Start
29 May 2025, 23:00
Contract End
30 May 2026, 22:59
Category
n/a
CPV
33124120 - Diagnostic ultrasound devices
Region
n/a
Awarded To
Attune Neurosciences Inc
Official Source
Open Find a Tender

Description

The University of Plymouth requires a ultrasound neuromodulation device which is designed for human use, specifically for non-invasive brain modulation. It is not a High Intensity Focused Ultrasound (HIFU) device and is not intended for surgery or tissue ablation. The system will utilize a multi-phased array transducer with 256 elements, with 128 elements positioned on each side of the head, targeting the temples. Acoustic simulation is included to optimize targeting and effectiveness. An MR-compatible version of the device is available for precise positioning and integration with imaging. Additionally, the system incorporates facial recognition to facilitate individualized device registration and setup for each participant.

Linked Documents

No linked documents found for this notice.

Opportunity Context

Lots

Lot 1 Status: complete

Lot 1 SME Suitable: Yes

Documents

Document Description: Not published

Raw Notice JSON

Expand raw payload
{
  "awards": [
    {
      "aboveThreshold": true,
      "contractPeriod": {
        "endDate": "2026-05-30T23:59:59+01:00",
        "startDate": "2025-05-30T00:00:00+01:00"
      },
      "documents": [
        {
          "datePublished": "2025-05-20T17:18:29+01:00",
          "description": "Transparency notice on Find a Tender",
          "documentType": "awardNotice",
          "format": "text/html",
          "id": "023484-2025",
          "noticeType": "UK5",
          "url": "https://www.find-tender.service.gov.uk/Notice/023484-2025"
        }
      ],
      "id": "1",
      "items": [
        {
          "additionalClassifications": [
            {
              "description": "Diagnostic ultrasound devices",
              "id": "33124120",
              "scheme": "CPV"
            }
          ],
          "deliveryAddresses": [
            {
              "country": "GB",
              "countryName": "United Kingdom",
              "region": "UKK41"
            }
          ],
          "id": "1",
          "relatedLot": "1"
        }
      ],
      "mainProcurementCategory": "goods",
      "milestones": [
        {
          "dueDate": "2025-05-30T23:59:59+01:00",
          "id": "1",
          "status": "scheduled",
          "type": "futureSignatureDate"
        }
      ],
      "relatedLots": [
        "1"
      ],
      "status": "pending",
      "suppliers": [
        {
          "id": "GB-PPON-PDPC-6183-TQJP",
          "name": "Attune Neurosciences Inc"
        }
      ],
      "value": {
        "amount": 337000,
        "amountGross": 337000,
        "currency": "GBP"
      }
    }
  ],
  "buyer": {
    "id": "GB-UKPRN-10007801",
    "name": "University of Plymouth"
  },
  "date": "2025-05-20T17:18:29+01:00",
  "id": "023484-2025",
  "initiationType": "tender",
  "language": "en",
  "ocid": "ocds-h6vhtk-051980",
  "parties": [
    {
      "additionalIdentifiers": [
        {
          "id": "PQHL-4825-PGGL",
          "scheme": "GB-PPON"
        }
      ],
      "address": {
        "country": "GB",
        "countryName": "United Kingdom",
        "locality": "Plymouth",
        "postalCode": "PL4 8AA",
        "region": "UKK41",
        "streetAddress": "Drakes Circus"
      },
      "contactPoint": {
        "email": "supplier@plymouth.ac.uk"
      },
      "details": {
        "classifications": [
          {
            "description": "Public authority - sub-central government",
            "id": "publicAuthoritySubCentralGovernment",
            "scheme": "UK_CA_TYPE"
          }
        ],
        "url": "https://www.plymouth.ac.uk/"
      },
      "id": "GB-UKPRN-10007801",
      "identifier": {
        "id": "10007801",
        "scheme": "GB-UKPRN"
      },
      "name": "University of Plymouth",
      "roles": [
        "buyer"
      ]
    },
    {
      "address": {
        "country": "US",
        "countryName": "United States",
        "locality": "San Francisco",
        "postalCode": "94107",
        "region": "US",
        "streetAddress": "2325 3rd Street, Suite 424"
      },
      "contactPoint": {
        "email": "sales@attuneneuro.com"
      },
      "details": {
        "scale": "sme",
        "url": "http://www.attuneneuro.com",
        "vcse": false
      },
      "id": "GB-PPON-PDPC-6183-TQJP",
      "identifier": {
        "id": "PDPC-6183-TQJP",
        "scheme": "GB-PPON"
      },
      "name": "Attune Neurosciences Inc",
      "roles": [
        "supplier"
      ]
    }
  ],
  "tag": [
    "award",
    "contract"
  ],
  "tender": {
    "description": "The University of Plymouth requires a ultrasound neuromodulation device which is designed for human use, specifically for non-invasive brain modulation. \nIt is not a High Intensity Focused Ultrasound (HIFU) device and is not intended for surgery or tissue ablation. The system will utilize a multi-phased array transducer with 256 elements, with 128 elements positioned on each side of the head, targeting the temples. Acoustic simulation is included to optimize targeting and effectiveness. An MR-compatible version of the device is available for precise positioning and integration with imaging. Additionally, the system incorporates facial recognition to facilitate individualized device registration and setup for each participant.",
    "documents": [
      {
        "description": "Not published",
        "documentType": "conflictOfInterest",
        "id": "conflictOfInterest"
      }
    ],
    "id": "MW/UoP/Ultrasound_Neuromodulation/102/25",
    "legalBasis": {
      "id": "2023/54",
      "scheme": "UKPGA",
      "uri": "https://www.legislation.gov.uk/ukpga/2023/54/contents"
    },
    "lots": [
      {
        "id": "1",
        "status": "complete",
        "suitability": {
          "sme": true,
          "vcse": true
        }
      }
    ],
    "procurementMethod": "direct",
    "procurementMethodDetails": "Direct award",
    "procurementMethodRationale": "This supplier is the sole owner and manufacturer of a multi-phased array system for human transcranial focused ultrasound research with 256 elements, with 128 elements positioned on each side of the head, targeting the temples. \nAcoustic simulation is included to optimize targeting and effectiveness. An MR-compatible version of the device is available for precise positioning and integration with imaging.\nAdditionally, the system incorporates facial recognition to facilitate individualized device registration and setup for \neach participant.\nThis device is a prototype designed for human use, specifically for non-invasive brain modulation. It is understood to be a prototype/novel good to be used for the purposes of research, experiment, study or development.\nThis allows for a direct award to a supplier under the Procurement Act 2023, Schedule 5, Paragraph 2 (c) \nThe device will be used by the University as part of the Advanced Research + Invention Agency  (ARIA) funded research programme.\nFurther details; https://www.plymouth.ac.uk/news/6-5m-project-aims-to-revolutionise-mental-health-treatment-using-ultrasound\nAdditional Information:\nNo Preliminary Market Engagement Notice (UK2) has been issued due to the prototype nature of this goods.\nInternal Conflict Assessment has been completed.\nThe Supplier is not understood to be an Excluded Supplier as defined by  the Procurement Act 2023, Section 57",
    "procurementMethodRationaleClassifications": [
      {
        "id": "prototypesDevelopment"
      },
      {
        "id": "defenceSecurityOperational"
      }
    ],
    "status": "complete",
    "title": "Ultrasound Neuromodulation Device (Transducer)"
  }
}