← Back to opportunities

Dry heat sterilizer for animal bedding and cages

University Of Edinburgh

Buyer Contact Info

Buyer Name: University Of Edinburgh

Buyer Address: Charles Stewart House, 9-16 Chambers Street, Edinburgh, UKM75, EH1 1HT

Contact Email: jpike2@ed.ac.uk

Contact Telephone: +44 1316502759

Status
complete
Procedure
limited
Value
380000.0 GBP
Published
20 May 2025, 00:00
Deadline
n/a
Contract Start
n/a
Contract End
n/a
Category
goods
CPV
42000000
Region
n/a
Awarded To
Process Control Solutions
Official Source
Open Public Contracts Scotland

Description

The University provides accommodation for a large volume of animals in the course of it’s day to day work. Regular sterilization of bedding and cages is critical to ensure the health and wellbeing of animals and to comply with bio-security controls set by the government and by accepted best-practice (such as avoiding the propagation of infectious diseases). In recent months an incumbent steam-based sterilizer system has failed on a regular basis, placing these bio-security and welfare controls at risk. Steam based machines are time consuming to build and maintain; in order to avoid an operational incident and provide biosecurity assurance as soon as possible the University has decided it should urgently procure an immediate solution, ahead of making long term plans for the replacement/upgrade of such machines. It is believed that a new type of device – a dry-heat based steriliser – would be the most appropriate solution, as in principle this is a simpler device which could be delivered and built faster than a steam counterpart. On the basis of; - Urgent circumstances which the University could not reasonably foresee or control - It is believed there may only be one supplier on the market who has an established dry-heat proposition with a prior service record encompassing a reasonable period of time The University is notifying the market it plans to undertake a Negotiated Procedure Without Prior Call for Competition. The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still. Value is an estimate consisting of GBP 380k expected cost with GBP 25k contingency.

Linked Documents

Some PCS documents require login and recording interest on the source portal before download links are available.

No linked documents found for this notice.

Opportunity Context

More Information Links

External Link: https://www.publiccontractsscotland.gov.uk/search/show/search_view.aspx?ID=MAY530683

Link Title: Dry heat sterilizer for animal bedding and cages

Link Description: The University provides accommodation for a large volume of animals in the course of it’s day to day work. Regular sterilization of bedding and cages is critical to ensure the health and wellbeing of animals and to comply with bio-security controls set by the government and by accepted best-practice (such as avoiding the propagation of infectious diseases). In recent months an incumbent steam-based sterilizer system has failed on a regular basis, placing these bio-security and welfare controls at risk. Steam based machines are time consuming to build and maintain; in order to avoid an operational incident and provide biosecurity assurance as soon as possible the University has decided it should urgently procure an immediate solution, ahead of making long term plans for the replacement/upgrade of such machines. It is believed that a new type of device – a dry-heat based steriliser – would be the most appropriate solution, as in principle this is a simpler device which could be delivered and built faster than a steam counterpart. On the basis of; - Urgent circumstances which the University could not reasonably foresee or control - It is believed there may only be one supplier on the market who has an established dry-heat proposition with a prior service record encompassing a reasonable period of time The University is notifying the market it plans to undertake a Negotiated Procedure Without Prior Call for Competition. The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still. Value is an estimate consisting of GBP 380k expected cost with GBP 25k contingency.

Lots

Lot Description: Technical requirements A dry heat sterilizer is required for the routine sterilization of assembled animal cages, bedding and other thermostable items involved in laboratory animal science. General characteristics: -Electrically powered heating, either 240V (2-phase) or 400V (3-phase) -Operating temperature of 140 deg C for routine use, no higher than 210°C at any time -Air circulation required to ensure even temperature distribution throughout static holding period -Intake air must be filtered to <0.3um (micro-metre) -Exhaust air must be filtered to <0.3um (micro-metre) -Throughput must be able to exceed 3320 cages per working week -There are no weight constraints Dimensions: Internal chamber dimensions should not be LESS than -Width 1000mm -Depth 2300mm -Height 2130mm Must be able to accommodate logistics trolleys and plenum racks for (e.g.) GM500 mouse IVC cages (Tecniplast) and must be able to process 3320 assembled mouse cages in a standard working week (5 days, 8 hours per day). You may include scheduled start and unattended cycle end times. External device dimensions should NOT EXCEED -Width 3600mm -Depth 3150mm -Height 2750mm Design considerations The sterilizer may be pit mounted. The door openings should be at opposite sides of the sterilizer so that un-sterile cargo is loaded from the external side, and sterile cargo is unloaded from the internal side (pass-through design). Human Machine Interface (“HMI”) (i.e. control panel) controls should be located on the external side, with the ability to control cycle operation and safely open doors from the internal side as well. There needs to be the capacity to save at least 10 configured control settings for different load types. Doors should have an airtight seal, preferably an inflatable gasket-type. Both doors must interlock when the machine is operating. When a cycle fail occurs, or an emergency stop is used, only the door on the side that initiated that cycle should be unlocked until the control system is reset. The existing stainless steel facia [surrounding an obsolete sterilizer] needs to be reinstated to seal with all existing finished surfaces to re-create an airtight barrier between clean and dirty access doors. The floor of the cargo chamber must be flush or near flush with the finished floor level on both sides of the sterilizer. This is so heavy loads can be easily wheeled in and out. The maximum threshold at each door is 15mm and the threshold must be bevelled for smooth transit. Extracted air must be mechanically exhausted via ducting to the outside to minimise cycle time. Each operation must be recorded on paper at the Human-Machine Interface (control panel), and must also have the capacity to save electronic run data in an accessible format . Alarm history must also be stored. The steriliser must have overtemperature sensors and control systems independent of the main controls in case of sensor failure in the main circuit. An audible alarm must sound in cases of overtemperature and failed airflow. Full validation of various load types must be achievable at our location. Access for installation is good, with double doorway and no steps. The sterilizer must be CE certified. You must also be able to provide customer references for a closely matched sterilizer and provide reliability information for equivalent machines in similar environments for a reasonable period of time to give high degree confidence.

Lot 1 Status: complete

Lot 1 Has Options: No

Documents

Document Title: Dry heat sterilizer for animal bedding and cages

Document Description: The University provides accommodation for a large volume of animals in the course of it’s day to day work. Regular sterilization of bedding and cages is critical to ensure the health and wellbeing of animals and to comply with bio-security controls set by the government and by accepted best-practice (such as avoiding the propagation of infectious diseases). In recent months an incumbent steam-based sterilizer system has failed on a regular basis, placing these bio-security and welfare controls at risk. Steam based machines are time consuming to build and maintain; in order to avoid an operational incident and provide biosecurity assurance as soon as possible the University has decided it should urgently procure an immediate solution, ahead of making long term plans for the replacement/upgrade of such machines. It is believed that a new type of device – a dry-heat based steriliser – would be the most appropriate solution, as in principle this is a simpler device which could be delivered and built faster than a steam counterpart. On the basis of; - Urgent circumstances which the University could not reasonably foresee or control - It is believed there may only be one supplier on the market who has an established dry-heat proposition with a prior service record encompassing a reasonable period of time The University is notifying the market it plans to undertake a Negotiated Procedure Without Prior Call for Competition. The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still. Value is an estimate consisting of GBP 380k expected cost with GBP 25k contingency.

Raw Notice JSON

Expand raw payload
{
  "awards": [
    {
      "id": "NCA31110-1",
      "relatedLots": [
        "1"
      ],
      "suppliers": [
        {
          "id": "org-14",
          "name": "Process Control Solutions"
        }
      ]
    }
  ],
  "buyer": {
    "id": "org-13",
    "name": "University Of Edinburgh"
  },
  "contracts": [
    {
      "awardID": "NCA31110-1",
      "dateSigned": "2025-05-20T00:00:00Z",
      "id": "NCA31110-1",
      "status": "active",
      "value": {
        "amount": 380000.0,
        "currency": "GBP"
      }
    }
  ],
  "date": "2025-05-20T00:00:00Z",
  "description": "The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still.\r\n (SC Ref:799260)",
  "id": "rls-7-MAY530683",
  "initiationType": "tender",
  "language": "EN",
  "links": [
    {
      "href": "https://api.publiccontractsscotland.gov.uk/v1/Notice?id=ocds-r6ebe6-0000799260",
      "rel": "canonical"
    }
  ],
  "ocid": "ocds-r6ebe6-0000799260",
  "parties": [
    {
      "address": {
        "locality": "Edinburgh",
        "postalCode": "EH1 1HT",
        "region": "UKM75",
        "streetAddress": "Charles Stewart House, 9-16 Chambers Street"
      },
      "contactPoint": {
        "email": "jpike2@ed.ac.uk",
        "telephone": "+44 1316502759",
        "url": "http://"
      },
      "details": {
        "classifications": [
          {
            "id": "Body governed by public law",
            "scheme": "TED_CA_TYPE"
          },
          {
            "description": "Education",
            "id": "09",
            "scheme": "COFOG"
          }
        ],
        "url": "http://www.ed.ac.uk"
      },
      "id": "org-13",
      "identifier": {
        "legalName": "University Of Edinburgh"
      },
      "name": "University Of Edinburgh",
      "roles": [
        "buyer"
      ]
    },
    {
      "address": {
        "locality": "SHREWSBURY",
        "postalCode": "01545",
        "region": "US",
        "streetAddress": "577A Hartford Tpke"
      },
      "contactPoint": {
        "telephone": "+44 5083664363"
      },
      "details": {
        "scale": "large",
        "url": "http://"
      },
      "id": "org-14",
      "identifier": {
        "legalName": "Process Control Solutions"
      },
      "name": "Process Control Solutions",
      "roles": [
        "supplier"
      ]
    },
    {
      "address": {
        "locality": "Edinburgh"
      },
      "contactPoint": {
        "url": "http://"
      },
      "id": "org-15",
      "identifier": {
        "legalName": "Edinburgh Sheriff Court"
      },
      "name": "Edinburgh Sheriff Court",
      "roles": [
        "reviewBody"
      ]
    }
  ],
  "tag": [
    "award",
    "contract"
  ],
  "tender": {
    "classification": {
      "id": "42000000",
      "scheme": "CPV"
    },
    "coveredBy": [
      "GPA"
    ],
    "description": "The University provides accommodation for a large volume of animals in the course of it\u00e2\u0080\u0099s day to day work. Regular sterilization of bedding and cages is critical to ensure the health and wellbeing of animals and to comply with bio-security controls set by the government and by accepted best-practice (such as avoiding the propagation of infectious diseases).\r\n In recent months an incumbent steam-based sterilizer system has failed on a regular basis, placing these bio-security and welfare controls at risk. Steam based machines are time consuming to build and maintain; in order to avoid an operational incident and provide biosecurity assurance as soon as possible the University has decided it should urgently procure an immediate solution, ahead of making long term plans for the replacement/upgrade of such machines. It is believed that a new type of device \u00e2\u0080\u0093 a dry-heat based steriliser \u00e2\u0080\u0093 would be the most appropriate solution, as in principle this is a simpler device which could be delivered and built faster than a steam counterpart.\r\n On the basis of;\r\n -\tUrgent circumstances which the University could not reasonably foresee or control\r\n -\tIt is believed there may only be one supplier on the market who has an established dry-heat proposition with a prior service record encompassing a reasonable period of time\r\n The University is notifying the market it plans to undertake a Negotiated Procedure Without Prior Call for Competition.\r\n The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still.\r\n Value is an estimate consisting of GBP 380k expected cost with GBP 25k contingency.",
    "documents": [
      {
        "description": "The University provides accommodation for a large volume of animals in the course of it\u00e2\u0080\u0099s day to day work. Regular sterilization of bedding and cages is critical to ensure the health and wellbeing of animals and to comply with bio-security controls set by the government and by accepted best-practice (such as avoiding the propagation of infectious diseases).\r\n In recent months an incumbent steam-based sterilizer system has failed on a regular basis, placing these bio-security and welfare controls at risk. Steam based machines are time consuming to build and maintain; in order to avoid an operational incident and provide biosecurity assurance as soon as possible the University has decided it should urgently procure an immediate solution, ahead of making long term plans for the replacement/upgrade of such machines. It is believed that a new type of device \u00e2\u0080\u0093 a dry-heat based steriliser \u00e2\u0080\u0093 would be the most appropriate solution, as in principle this is a simpler device which could be delivered and built faster than a steam counterpart.\r\n On the basis of;\r\n -\tUrgent circumstances which the University could not reasonably foresee or control\r\n -\tIt is believed there may only be one supplier on the market who has an established dry-heat proposition with a prior service record encompassing a reasonable period of time\r\n The University is notifying the market it plans to undertake a Negotiated Procedure Without Prior Call for Competition.\r\n The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still.\r\n Value is an estimate consisting of GBP 380k expected cost with GBP 25k contingency.",
        "documentType": "awardNotice",
        "format": "text/html",
        "id": "MAY530683",
        "title": "Dry heat sterilizer for animal bedding and cages",
        "url": "https://www.publiccontractsscotland.gov.uk/search/show/search_view.aspx?ID=MAY530683"
      }
    ],
    "id": "NCA31110",
    "items": [
      {
        "deliveryAddresses": [
          {
            "region": "UKM75"
          }
        ],
        "deliveryLocation": {
          "description": "City of Edinburgh"
        },
        "id": "1",
        "relatedLot": "1"
      }
    ],
    "legalBasis": {
      "id": "32014L0024",
      "scheme": "CELEX"
    },
    "lots": [
      {
        "description": "Technical requirements\r\n A dry heat sterilizer is required for the routine sterilization of assembled animal cages, bedding and other thermostable items involved in laboratory animal science.\r\n General characteristics:\r\n -Electrically powered heating, either 240V (2-phase) or 400V (3-phase)\r\n -Operating temperature of 140 deg C for routine use, no higher than 210\u00c2\u00b0C at any time\r\n -Air circulation required to ensure even temperature distribution throughout static holding period\r\n -Intake air must be filtered to \u003c0.3um (micro-metre)\r\n -Exhaust air must be filtered to \u003c0.3um (micro-metre)\r\n -Throughput must be able to exceed 3320 cages per working week\r\n -There are no weight constraints\r\n Dimensions:\r\n Internal chamber dimensions should not be LESS than\r\n -Width 1000mm\r\n -Depth 2300mm\r\n -Height 2130mm\r\n Must be able to accommodate logistics trolleys and plenum racks for (e.g.) GM500 mouse IVC cages (Tecniplast) and must be able to process 3320 assembled mouse cages in a standard working week (5 days, 8 hours per day). You may include scheduled start and unattended cycle end times.\r\n External device dimensions should NOT EXCEED\r\n -Width 3600mm\r\n -Depth 3150mm\r\n -Height 2750mm\r\n Design considerations\r\n The sterilizer may be pit mounted. The door openings should be at opposite sides of the sterilizer so that un-sterile cargo is loaded from the external side, and sterile cargo is unloaded from the internal side (pass-through design). Human Machine Interface (\u00e2\u0080\u009cHMI\u00e2\u0080\u009d) (i.e. control panel) controls should be located on the external side, with the ability to control cycle operation and safely open doors from the internal side as well. There needs to be the capacity to save at least 10 configured control settings for different load types.\r\n Doors should have an airtight seal, preferably an inflatable gasket-type. Both doors must interlock when the machine is operating. When a cycle fail occurs, or an emergency stop is used, only the door on the side that initiated that cycle should be unlocked until the control system is reset. The existing stainless steel facia [surrounding an obsolete sterilizer] needs to be reinstated to seal with all existing finished surfaces to re-create an airtight barrier between clean and dirty access doors.\r\n The floor of the cargo chamber must be flush or near flush with the finished floor level on both sides of the sterilizer. This is so heavy loads can be easily wheeled in and out. The maximum threshold at each door is 15mm and the threshold must be bevelled for smooth transit.\r\n Extracted air must be mechanically exhausted via ducting to the outside to minimise cycle time.\r\n Each operation must be recorded on paper at the Human-Machine Interface (control panel), and must also have the capacity to save electronic run data in an accessible format . Alarm history must also be stored.\r\n The steriliser must have overtemperature sensors and control systems independent of the main controls in case of sensor failure in the main circuit. An audible alarm must sound in cases of overtemperature and failed airflow.\r\n Full validation of various load types must be achievable at our location. Access for installation is good, with double doorway and no steps.\r\n The sterilizer must be CE certified. You must also be able to provide customer references for a closely matched sterilizer and provide reliability information for equivalent machines in similar environments for a reasonable period of time to give high degree confidence.",
        "hasOptions": false,
        "id": "1",
        "status": "complete"
      }
    ],
    "mainProcurementCategory": "goods",
    "procurementMethod": "limited",
    "procurementMethodDetails": "Award procedure without prior publication of a call for competition",
    "procurementMethodRationale": "The University provides accommodation for a large volume of animals in the course of it\u00e2\u0080\u0099s day to day work. Regular sterilization of bedding and cages is critical to ensure the health and wellbeing of animals and to comply with bio-security controls set by the government and by accepted best-practice (such as avoiding the propagation of infectious diseases).\r\n In recent months an incumbent steam-based sterilizer system has failed on a regular basis, placing these bio-security and welfare controls at risk. Steam based machines are time consuming to build and maintain; in order to avoid an operational incident and provide biosecurity assurance as soon as possible the University has decided it should urgently procure an immediate solution, ahead of making long term plans for the replacement/upgrade of such machines. It is believed that a new type of device \u00e2\u0080\u0093 a dry-heat based steriliser \u00e2\u0080\u0093 would be the most appropriate solution, as in principle this is a simpler device which could be delivered and built faster than a steam counterpart.\r\n On the basis of;\r\n -\tUrgent circumstances which the University could not reasonably foresee or control\r\n -\tIt is believed there may only be one supplier on the market who has an established dry-heat proposition with a prior service record encompassing a reasonable period of time\r\n The University is notifying the market it plans to undertake a Negotiated Procedure Without Prior Call for Competition.\r\n The University will observe a ten (10) day Stand-Still in line with the Public Contract Regulations (Scotland) 2015. Any suppliers wishing to challenge this procedure should do so with the individual stated on the notice, during this Stand-Still.",
    "procurementMethodRationaleClassifications": [
      {
        "description": "The works, supplies or services can be provided only by a particular economic operator due to absence of competition for technical reasons",
        "id": "D_TECHNICAL",
        "scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL"
      }
    ],
    "status": "complete",
    "title": "Dry heat sterilizer for animal bedding and cages"
  }
}